    "type": "URL",
    "parsed_data": "https://linkedsystems.uk/system/instance/TOOL0022_2490/current/"
  },
  {
    "type": "21.T11148/8eb858ee0b12e8e463a5",
    "parsed_data": "{\"identifierValue\":\"http://hdl.handle.net/21.T11998/0000-001A-3905-F\",\"identifierType\":\"Handle\"}"
  },
  {
    "type": "21.T11148/aa24da8ba845c23ea75c",
    "parsed_data": "1.0"
  },
  {
    "type": "21.T11148/e0efc41346cda4ba84ca",
    "parsed_data": "https://linkedsystems.uk/system/instance/TOOL0022_2490/current/"
  },
  {
    "type": "21.T11148/ab8d232261b9b60ba559",
    "parsed_data": "Sea-Bird SBE 37-IM MicroCAT C-T Sensor"
  },
  {
    "type": "21.T11148/4eaec4bc0f1df68ab2a7",
    "parsed_data": "[{\"Owner\": {\"ownerName\":\"National Oceanography Centre\",\"ownerContact\":\"someone@example.org\",\"ownerIdentifier\":{\"ownerIdentifierValue\":\"http://vocab.nerc.ac.uk/collection/B75/current/ORG00009/\",\"ownerIdentifierType\":\"URL\"}}}]"
  },
  {
    "type": "21.T11148/1f3e82ddf0697a497432",
    "parsed_data": "[{\"Manufacturer\":{\"manufacturerName\":\"Sea-Bird Scientific\",\"manufacturerIdentifier\":{\"manufacturerIdentifierValue\":\"http://vocab.nerc.ac.uk/collection/L35/current/MAN0013/\",\"manufacturerIdentifierType\":\"URL\"}}}]"
  },
  {
    "type": "21.T11148/c1a0ec5ad347427f25d6",
    "parsed_data": "[{\"modelName\":\"Sea-Bird SBE 37 MicroCat IM-CT with optional pressure (submersible) CTD sensor series\",\"modelIdentifier\":{\"modelIdentifierValue\":\"http://vocab.nerc.ac.uk/collection/L22/current/TOOL0022/\",\"modelIdentifierType\":\"URL\"}}]"
  },
  {
    "type": "21.T11148/f1627ce85386d8d75078",
    "parsed_data": "A high accuracy conductivity and temperature recorder with an optional pressure sensor designed for deployment on moorings. The IM model has an inductive modem for real-time data transmission plus internal flash memory data storage."
  },
  {
    "type": "21.T11148/c60c8da7fff2ef4f98ce",
    "parsed_data": "[{\"InstrumentType\":{\"instrumentTypeName\":\"water temperature sensor\",\"instrumentTypeIdentifier\":{\"instrumentTypeIdentifierValue\":\"http://vocab.nerc.ac.uk/collection/L05/current/134/\",\"instrumentTypeIdentifierType\":\"URL\"}}},{\"instrumentType\":{\"instrumentTypeName\":\"salinity sensor\",\"InstrumentTypeIdentifier\":{\"instrumentTypeIdentifierValue\":\"http://vocab.nerc.ac.uk/collection/L05/current/350/\",\"instrumentTypeIdentifierType\":\"URL\"}}}]"
  },
  {
    "type": "21.T11148/72928b84e060d491ee41",
    "parsed_data": "[{\"MeasuredVariable\":\"http://vocab.nerc.ac.uk/collection/P01/current/CNDCPR01/\"},{\"MeasuredVariable\":\"http://vocab.nerc.ac.uk/collection/P01/current/PSALPR01/\"},{\"MeasuredVariable\":\"http://vocab.nerc.ac.uk/collection/P01/current/TEMPPR01/\"},{\"MeasuredVariable\":\"http://vocab.nerc.ac.uk/collection/P01/current/PREXMCAT/\"}]"
  },
  {
    "type": "21.T11148/22c62082a4d2d9ae2602",
    "parsed_data": "[{\"date\":{\"dateValue\":\"1999-11-01\",\"dateType\":\"Commissioned\"}}]"
  },
  {
    "type": "21.T11148/eb3c713572f681e6c4c3",
    "parsed_data": "[{\"AlternateIdentifier\":{\"alternateIdentifierValue\":\"2490\",\"alternateIdentifierType\":\"serialNumber\"}}]"
  },
  {
    "type": "21.T11148/178fb558abc755ca7046",
    "parsed_data": "[{\"RelatedIdentifier\":{\"relatedIdentifierValue\":\"https://www.bodc.ac.uk/data/documents/nodb/pdf/37imbrochurejul08.pdf\",\"relatedIdentifierType\": \"URL\",\"relationType\":\"IsDescribedBy \"}}]"
  }
]